Mô tả
Máy đo hiện sóng Fluke 124
Thông số kỹ thuật:
|
| Specifications | ||
| Oscilloscope Bandwidth | Fluke 124: | 40 MHz |
| Dual input True RMS Meter | Vdc, Vac, Vac+Vdc, Ohms,Continuity , Diode-test | |
| Current, °C, °F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset | ||
| TrendPlot Recording | Automatic vertical scaling and time compression. | |
| Display the actual, MIN, MAX and AVG reading. | ||
| Cursors | Fluke 125/124: | ∆T, 1/∆T, V, ∆V, rise- and fall time |
| Real-time sample rate | 25 MS/s | |
| Equivalent sampling rate | up to 2.5 GS/s (125, 124) or 1.25 GS/s (123). | |
| Inputs and digitizers | 2 | |
| Timebase range | Fluke 125/124: | 20 ns – 1 min/div |
| Fluke 123: | 10 ns – 1 min/div | |
| Input sensitivity | 5 mV – 500 V/div | |
| Trigger types | Connect-and-View™, Free Run, Single Shot, Edge, Video, External | |
| Glitch capture | 40 ns | |
| Scope measurements | Automatic measurements: 26 (all instruments) On top, Fluke 125 has additional measurement functions for Power (W), VA, VAR and Power Factor (PF) for single phase and balanced-three-phase (delta) power systems. | |
| Harmonics mode | Fluke 125 has capbility to analyze the harmonics contents of power signals. See below for details. | |
| Maximum record length | 512 min/max pts per input | |
| Memory | Fluke 125/124: | 20 screens and setups |
| Fluke 123: | 10 screens and setups | |
| Additional Power measurement capabilities (Fluke 125 only) | ||
| Measurement types: | • | Watt, |
| • | VA, | |
| • | VAR, | |
| • | Power Factor (PF) | |
| Power configuration: | Single phase or balanced three-phase (delta-configuration) mains supply | |
| Voltage measurement | Channel A; using STL120, voltage probe or direct input | |
| Current measurement | Channel B, using i400s (included) or other compatible current clamp | |
| Current Clamp or Shunt sensitivity: | 0.1 / 1 / 10 / 100 / 1000 mV/A, 10 mV/mA and 400 mV/A. | |
| Harmonics Mode (Fluke 125 only) | ||
| Converts waveform information into a harmonics display (using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic | ||
| Analyzed waveform: | Voltage waveform(Ch.A), Current wavefrom (Ch.B) or Power (Ch.A x Ch.B), automatically generated. | |
| Harmonics Frequency range: | DC up to 33rd harmonic (for fundamental up to 60 Hz); | |
| DC up to 24th harmonic (for fundamental up to 400 Hz). | ||
| Display | Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental | |
| Measurements: | Relative amplitude of individual harmonics; | |
| THD in %r or %f. | ||
| Environmental Specifications | ||
| Operating Temperature | 0 ºC to 50 ºC | |
| Storage Temperature | -20 °C to +60 °C | |
| Operating Altitude | 3,000 m | |
| Mechanical & General Specifications | ||
| Size | 232 x 115 x 50 mm | |
| Weight | 1.2 kg | |
| Warranty | 3-years on main instrument, 1-year on accessories | |
| Battery Life | 7 hrs using NiMH | |
| RS232/USB Interface | Optically isolated via optional PM9080 or OC4USB for interfacing to Printer or PC | |